1 Features
• Supports ECG and respiration impedance
measurement; configurable as 2-channel ECG or
1-channel ECG + 1-channel Respiration
• Can be used in IEC 60601-2-47:2012/(R)2016 and
IEC 60601-2-27:2011(R)2016 compliant systems
• 222 μA/channel while operating as 2-channel ECG
• Integrated Pace pulse detection on 1 channel
• Supports a 3-lead ECG, extendable to 5 leads or
higher by operating two or more AFEs in parallel
• ECG signal chain:
– Single channel ECG acquisition up to 2.048
kHz
– 2 channel ECG acquisition up to 1.36 kHz/
channel
– RLD output to set body bias through third
electrode
– Programmable INA gain from 2~12
– >1 GΩ input impedance, CMRR > 100 dB
– Input noise (0.5-150 Hz): 13 μVpp at INA gain
of 3; 5 μVpp at INA gain of 12
– Integrated 370 Hz anti-aliasing low pass filter
– Mode for Continuous lead on/off detection
– Mode for Lead impedance measurement
• Bio-Z signal chain:
– Measurement of Bio-impedance over excitation
frequency from 30 kHz to 100 kHz
– Sine wave or square wave excitation
– Respiration impedance measurement: 45 mΩ-
pp noise on a baseline impedance of 2 kΩ
• Dual channel ECG channel:
– Bio-Z receiver configurable as a 2nd ECG
channel
• External clock and internal oscillator modes
• FIFO with 128-sample Depth, 24-bit word
• SPITM, I2C interfaces: Selectable by pin
• 2.6-mm × 2.6-mm DSBGA, 0.4-mm Pitch
• Supplies: Rx:1.7-1.9 V, IO:1.7-1.9 V
2 Applications
• Wireless patches for in-patient and out-patient
monitoring
• Event monitors for arrhythmia detection
• Hand-held ECG monitor
• Portable multi-lead ECG
• Patient vital sign monitoring: holter, event, stress
and telemedicine
3 Description
The AFE4960 can be configured as either a 2-channel
ECG receiver or as a 1-channel ECG receiver and
a respiration impedance channel. The AFE signal
chains can interface in a flexible manner to up to
4 electrodes. A Right Leg Drive (RLD) amplifier
output, can be used to set the body bias. The AFE
has DC lead biasing for lead on/off detection, and
AC lead biasing for measuring the lead impedance.
Pacemaker pulse detection is supported on one
channel.
All the signal chain outputs are converted by a single
ADC in well-defined time slots and stored as 24-bit
words in a 128-sample FIFO which can be read out
using a SPI or an I2C interface.
The AFE4960 is a fully integrated solution to realize
a 3-lead ECG system. Synchronized operation of two
AFEs in parallel can be used to realize a 5-lead ECG.
供应商 | 型号 | 品牌 | 批号 | 封装 | 库存 | 备注 | 价格 |
---|---|---|---|---|---|---|---|
TI |
25+ |
DSBGA |
9800000 |
原厂直接发货进口原装 |
|||
TI/德州仪器 |
25+ |
原厂封装 |
10280 |
原厂授权一级代理,专注军工、汽车、医疗、工业、新能源、电力! |
|||
TI德州仪器 |
22+ |
24000 |
原装正品现货,实单可谈,量大价优 |
||||
TI |
25+ |
3000 |
原厂原装,价格优势 |
||||
TEXAS INSTRUMENTS |
23+ |
SMD |
880000 |
明嘉莱只做原装正品现货 |
|||
TI |
24+ |
con |
35960 |
查现货到京北通宇商城 |
|||
TEXAS INSTRUMENTS/德州仪器 |
24+ |
原封装 |
19679 |
只做全新原装进口现货 |
|||
TI |
25+ |
原封装 |
66330 |
郑重承诺只做原装进口现货 |
|||
TI/德州仪器 |
25+ |
原厂封装 |
10280 |
||||
Texas Instruments |
36-DSBGA(2.63x2.46) |
60000 |
全新、原装 |
AFE4960 资料下载更多...
AFE4960 芯片相关型号
- 636N3I
- 636N5C
- 636N5I
- 636N6C
- 636N6I
- AFE4960YBGR
- AFE4960YBGR.A
- AFE4960YBGT
- AFE4960YBGT.A
- GQM2195G2E1R1CB12
- GQM2195G2E1R1CB12_V01
- GQM2195G2E1R1CB12-01A
- GQM2195G2E1R1WB12
- GQM2195G2E1R1WB12_V01
- GQM2195G2E1R1WB12-01A
- MEWT-33D-B
- MEWT-33D-BSLASHQ
- MEWT-33D-C
- MEWT-33D-CSLASHQ
- MEWT-33D-D
- MEWT-33D-DSLASHQ
- MEWT-33D-F
- MEWT-33D-FSLASHQ
- MEWT-33D-G
- MEWT-33D-GSLASHQ
- MEWT-33D-SSLASHQ
- NUC540-VE3N
Datasheet数据表PDF页码索引
- P1
- P2
- P3
- P4
- P5
- P6
- P7
- P8
- P9
- P10
- P11
- P12
- P13
- P14
- P15
- P16
- P17
- P18
- P19
- P20
- P21
- P22
- P23
- P24
- P25
- P26
- P27
- P28
- P29
- P30
- P31
- P32
- P33
- P34
- P35
- P36
- P37
- P38
- P39
- P40
- P41
- P42
- P43
- P44
- P45
- P46
- P47
- P48
- P49
- P50
- P51
- P52
- P53
- P54
- P55
- P56
- P57
- P58
- P59
- P60
- P61
- P62
- P63
- P64
- P65
- P66
- P67
- P68
- P69
- P70
- P71
- P72
- P73
- P74
- P75
- P76
- P77
- P78
- P79
- P80
- P81
- P82
- P83
- P84
- P85
- P86
- P87
- P88
- P89
- P90
- P91
- P92
- P93
- P94
- P95
- P96
- P97
- P98
- P99
- P100
- P101
- P102
- P103
- P104
- P105