The IM12-AI01-1I-1IU1R-H… isolating transducers transmit the analog measured signal
in a galvanically isolated manner. In addition,
the devices monitor the input signals for exceeding or falling below an adjustable limit
value. The devices are suitable for operation
in Zone 2. Passive 2-wire transducers, as well
as active and passive HART transmitters, can
be used on the devices.
The IM12-AI01-1I-1IU1R-HPR/24VDC/CC isolating transducer is equipped with input circuits of 4…20 mA and output circuits of 4…
20 mA (either as source or sink) and 1…5 V
(source). Input signals are transmitted in the
3.8 mA…20.5 mA range 1:1 to the output
[A1A] without impairment. Alternatively, the input current signal is provided proportionally
as a normalized voltage in the 1 V…5 V range
(source) at output [A2A]. In addition, digital
signals can also be transmitted bidirectionally
in accordance with the HART protocol.
The input circuit is monitored for wire breaks
and short circuits. Via the Power-Bridge connection, the device can be supplied and a
group fault signal can be transmitted.
The devices are configured via DIP and rotary
coding switches on the device side. The analog output to be used (current output A1A or
voltage output A2A) as well as the switching
point (5…20 mA in 1-mA increments), the effective direction (NC/NO) and the switching
behavior of the relay output (A1D) when exceeding/falling below the set switching point
are adjustable.
The devices have a green power LED (Pwr).
Two red status LEDs are provided to indicate
wire breaks and short circuits, respectively, in the input circuit. A fault in the input circuit causes the red LED to flash according to
NE44. Two yellow status LEDs indicate the
switching status and the set effective direction of the relay output. In the event of a wire
break ( 22 mA) in
the input circuit, a current value of < 3.5 mA
or a voltage value of < 0.875 V is output at the
analog output.
The device can be used in safety circuits up to
SIL 2 (high and low demand according to IEC
61508) (hardware fault tolerance HFT = 0).
The device is equipped with removable
spring-type terminals.
■ Isolating transducer
■ Complete galvanic isolation
■ Input reverse-polarity protected
■ Removable spring type terminals
■ Power bridge (connector incl. in delivery)
■ Use in Zone 2
■ SIL 2
7580942 资料下载更多...
7580942 芯片相关型号
TURCK相关芯片制造商
Datasheet数据表PDF页码索引
- P1
- P2
- P3
- P4
- P5
- P6
- P7
- P8
- P9
- P10
- P11
- P12
- P13
- P14
- P15
- P16
- P17
- P18
- P19
- P20
- P21
- P22
- P23
- P24
- P25
- P26
- P27
- P28
- P29
- P30
- P31
- P32
- P33
- P34
- P35
- P36
- P37
- P38
- P39
- P40
- P41
- P42
- P43
- P44
- P45
- P46
- P47
- P48
- P49
- P50
- P51
- P52
- P53
- P54
- P55
- P56
- P57
- P58
- P59
- P60
- P61
- P62
- P63
- P64
- P65
- P66
- P67
- P68
- P69
- P70
- P71
- P72
- P73
- P74
- P75
- P76
- P77
- P78
- P79
- P80
- P81
- P82
- P83
- P84
- P85
- P86
- P87
- P88
- P89
- P90
- P91
- P92
- P93
- P94
- P95
- P96
- P97
- P98
- P99
- P100
- P101
- P102
- P103
- P104
- P105
- P106
- P107
- P108
- P109
- P110