FEATURES
Digital Display for Parameter Setting and Monitoring
High Output Power for TEC: 12V20A
High Efficiency: >98%
No Heat Sink Required
Penal Mounting Design
Over Current Protected
Communication Function
Compact Size: 152.6mm(L)×76.0mm(W)×20.4mm(H)
DESCRIPTION
ATFC106D is designed for regulating an enclosed chamber
temperature by driving a TEC array and a fan array. In
addition, upon detecting the chamber temperature goes beyond
the safety windows, see the table below, it cuts off an AC
power switch by sending the relay control signal. The
ATFC106D is a digitally controlled TEC/fan assembly
controller for driving TEC assemblies with fans and
monitoring the working status at the same time. It allows
setting the parameters of the set-point temperature window, the
safety temperature window, monitoring the heat sink hot side
temperature, heat sink cold side temperature, and the chamber
temperature, as shown in Figure 1. The controller integrates a
digital display, a TEC controller, a fan controller, and
temperature controlled relay control output into one assembly,
see Figure 3.
In the controller, there are 2 control loops: TEC and Fan. The
former has a bi-directional output for achieving both heating
and cooling effects, the latter switches the fan on and off.
As shown in Figure 4, a digital display is used to show these
temperatures: Safety High Temperature, Safety Low
Temperature, Cool On Temperature, Heat On
Temperature, Satisfied, TEC Outside Temperature, TEC
Inside Temperature and Chamber Temperature. There are
8 LEDs indicating which of these temperatures is shown in
the display.
The Safety High Temperature, T1, is the temperature point
on which the chamber air temperature gets too high that the
load control relay is turned off, but the TECs keep cooling
down the chamber air.
The Cool On Temperature, T2, is the temperature point on
which triggers the TECs to start cooling down the chamber
air.
The Heat On Temperature, T3, is the temperature point on
which triggers the TECs to start heating up the chamber air.
The Safety Low Temperature, T4, is the temperature point
on which the chamber air temperature gets too low that the
load control relay is turned off, but the TECs keeps heating
up the chamber air. There is an option that when the chamber
temperature gets too low, the load control relay is not turned
off so that the load is still on and works as a heating element,
helping increase the chamber temperature.
The LED indication logic for the above 4 temperatures is
shown in Table 1.
供应商 | 型号 | 品牌 | 批号 | 封装 | 库存 | 备注 | 价格 |
---|---|---|---|---|---|---|---|
- |
2022+ |
SMD |
200000 |
原厂代理 终端免费提供样品 |
|||
- |
23+ |
SMD |
6800 |
专注配单,只做原装进口现货 |
|||
SMD |
23+ |
SMD |
400000 |
原厂授权代理,海外优势订货渠道。可提供大量库存,详 |
|||
Banner Engineering |
2022+ |
65 |
全新原装 货期两周 |
||||
Banner Engineering Corporation |
23+ |
原厂封装 |
436 |
现货常备产品原装 |
|||
MICROCHIP/微芯 |
21+ |
68LCQFP24.13x24.13 |
20000 |
MIC/微芯优势供应 实单必成 可开增值税票 |
|||
MICROCHIP/微芯 |
25+ |
25000 |
原厂原包 深圳现货 主打品牌 假一赔百 可开票! |
||||
ATMEL |
22+ |
SOP |
8200 |
全新原装现货!自家库存! |
|||
AT |
25+ |
SOP-8 |
2987 |
只售原装自家现货!诚信经营!欢迎来电! |
|||
ATMEL/爱特梅尔 |
2447 |
SOP |
100500 |
一级代理专营品牌!原装正品,优势现货,长期排单到货 |
ATFC106D 资料下载更多...
ATFC106D 芯片相关型号
- 10164986
- 5KP
- 67-06E
- AAS50A6V3
- AHVAHS2KV2X20MA
- AHVAN1KV20MA
- AHVAN2KV100MA
- AHVAN2R5KV20MA
- AMS5612
- AMS6915_V01
- AT06-08SX-OMXXX
- ATFC109D
- ATLS15A218
- ATLS25A219CH
- ATLS25A219D
- ATLS25A219GUI
- BL-2835W10
- BL-2835W10-16-R80
- BL-2835W10-34
- BL-2835W10-34-R80
- BL-2835W10-R80
- BL-B2134V-AT
- C01-5159-0008
- ES1B
- IDS-39-6
- P6SMB
- RS1A
- SM8ZXXCA
- SMBJ
ANALOGTECHNOLOGIES相关芯片制造商
Datasheet数据表PDF页码索引
- P1
- P2
- P3
- P4
- P5
- P6
- P7
- P8
- P9
- P10
- P11
- P12
- P13
- P14
- P15
- P16
- P17
- P18
- P19
- P20
- P21
- P22
- P23
- P24
- P25
- P26
- P27
- P28
- P29
- P30
- P31
- P32
- P33
- P34
- P35
- P36
- P37
- P38
- P39
- P40
- P41
- P42
- P43
- P44
- P45
- P46
- P47
- P48
- P49
- P50
- P51
- P52
- P53
- P54
- P55
- P56
- P57
- P58
- P59
- P60
- P61
- P62
- P63
- P64
- P65
- P66
- P67
- P68
- P69
- P70
- P71
- P72
- P73
- P74
- P75
- P76
- P77
- P78
- P79
- P80
- P81
- P82
- P83
- P84
- P85
- P86
- P87
- P88
- P89
- P90
- P91
- P92
- P93
- P94
- P95
- P96
- P97
- P98
- P99
- P100
- P101
- P102
- P103
- P104
- P105